Quality Water Treatment Solutions Since 1994

High Flow PolyHalt Cartridge TankIntegrated Cartridge Solutions with PolyHaltMade in USA of Foreign and Domestic Components

CASCADIAN® Integrated Cartridge Solutions

Unprecedented treatment options

 

The ICS line of cartridge filter solutions is designed from the ground up with quality, reliability and results in mind. You can count of ICS solutions to reliably treat water quality problems for years to come. Capable of treating up to 15 GPM with 1” connections ICS solutions are built from NSF approved components with cartridge filters specially designed for long lasting dependable results.

Where budget or space are a concern the ICS Solutions are a great alternative to our fully automatic CASCADIAN® Professional Solutions; Click here to learn more about CASCADIAN® Professional Solutions.

ICS Benefits:

  • Systems are fully assembled and ready install.
  • Easily install just about anywhere - no power or drain required.
  • Large filters result in fewer filter cartridge changes and less maintenance.
  • Easy Maintenance – simply change the cartridges in a few minutes.

Find the right ICS system for you

See answers to frequently asked questions about our ICS product line

Open the ICS product brochure

Open the PolyHalt® water conditioner brochure

Higher flow rate cartridge tank systems

 

Now with ICS systems you can treat;

  • Mineral / Hardness Deposits
  • Orange, Red, Brown, Black and Blue Stains
  • Etching and Pitting
  • Bad Taste and Odor (including chlorine)
  • Low pH Problems
  • Sediment and Solids
  • Appliance / Pipe Corrosion

ICS systems replace these traditional automatic water treatment technologies;

  • Water Softeners
  • Iron Filters
  • Reverse Osmosis Systems
  • Activated Carbon Filters (taste and odor)
  • Acid Neutralizing Filters (raises low pH)
  • Sediment Filters

How the PolyHalt® works:

The PolyHalt® cartridge works in three ways;

1. Holds in suspension (sequesters); soluble iron, manganese, silica and hardness minerals.

2. Protects plumbing and appliances from deposits and scale buildup and stains.

3. Forms a thin protective layer to protect against aggressive low pH waters.

Which ICS do you need?

To use this table simply find your water quality problem in the left column and to learn what treatment systems are designed to address that problem. Follow the link or links in the right hand columns.

ICS Problem Solving Chart
Your Water Problem Recommended ICS
P S5 SP SIP STP TO TP
Clear Iron and Manganese*
X   X X X   X
Colored Iron and Manganese**
  X X X X    
Hardness / Mineral Deposits
X   X X X   X
Low pH
X   X X X   X
Silica
X   X X X   X
Sediment
  X X X X    
Taste and Odor
        X X X
Number of Filters
1 1 1 2 2 2 1
*Clear Iron and Manganese: Water is clear but stains fixtures and appliances
**Colored Iron and Manganese: Water has red, orange or brown color and stains fixtures and appliances

CASCADIAN® ICS - System Descriptions

Select Single Filter Solutions

  1. P – PolyHalt®iron, manganese, hardness, etching, pipe and appliance protection.
    Prevents iron, manganese and hardness minerals from depositing and sticking to fixtures. Protects plumbing and fixtures from silica etching and corrosion. Protects plumbing and fixtures from low pH (acid) conditions by forming a thin protective coating on the surface.

  2. S5 – Sediment filtration down to 5 microns.
    Clears water of sediment and solids and protects downstream treatment and appliances.

  3. SP – Sediment with PolyHalt® and PolyCor Technology. Treats iron, manganese, hardness, etching, pipe and appliance protection.
    Clears water of sediment and solids and protects downstream treatment and appliances. With PolyCor technology the filter also prevents iron, manganese and hardness minerals from depositing and sticking to fixtures and it protects plumbing and fixtures from silica etching and corrosion and low pH (acid) conditions by forming a thin protective coating on the surface.

  4. TP - Taste and odor with PolyHalt® and PolyCor Technology. Treats iron, manganese, hardness, etching, pipe and appliance protection.
    Designed for water with minimal sediment needing taste and odor improvement. Filter one is designed to improve taste and odor and remove chlorine. Filter two Prevents iron, manganese and hardness minerals from depositing and sticking to fixtures. Protects plumbing and fixtures from silica etching and corrosion. Protects plumbing and fixtures from low pH (acid) conditions by forming a thin protective coating on the surface.

 

Select Double Filter Solutions

  1. SIP - Sediment, Soluble Iron with PolyHalt®and PolyCor Technology. Treats iron, manganese, hardness, etching, pipe and appliance protection.
    Filter one clears water of sediment and solids. Filter two removes iron and manganese ,and with PolyCor technology prevents iron, manganese and hardness minerals from depositing and sticking to fixtures. Filter two also protects plumbing and fixtures from silica etching and corrosion and low pH (acid) conditions by forming a thin protective coating on the surface.

  2. STP - Sediment, Taste & Odor with PolyHalt® and PolyCor Technology. Treats iron, manganese, hardness, etching, pipe and appliance protection.
    Filter one clears water of sediment and solids and protects downstream treatment and appliances. Filter two improves taste and odor and with PolyCor technology prevents iron, manganese and hardness minerals from depositing and sticking to fixtures. Filter two also protects plumbing and fixtures from silica etching and corrosion and low pH (acid) conditions by forming a thin protective coating on the surface.

  3. TO – Taste and odor.
    Two different activated carbon filters to improve taste and odor.


Triple Filter Solutions

SIT - Sediment, Iron Removal with Taste and Odor.
Filter one clears water of sediment and solids and protects downstream treatment and appliances. Filter two removes iron and manganese from the water. Filter three improves taste and odor.

As of 2014 we no longer build several triple filter ICS systems. We still build and sell filter replacement kits just not the systems.

ICS Systems No Longer Available Include: ICS-SI, ICS-SIT, ICS-SS51, and ICS-SS75

Furthermore:

In 2014 we renamed the ICS-PWC06 and ICS-PWC12 to ICS-STP06 and ICS-STP12 respectively. This was done to keep our ICS product names consistent.

 

Top of Page